A pressure switch with the ?change-over? switching function represents a particular version of a pressure switch with two switching outputs acting oppositely to change two circuits. A ?change-over? closes one circuit and simultaneously opens another circuit. Thus a ?change-over? simultaneously fulfils the event of a ?normally open? in addition to a ?normally closed? contact. Which means that, in operation, a ?change-over? can only ever have one connected circuit closed and something energised.
Application types of pressure switches with ?change-over? switching function
?Change-over? contacts are used to a much lesser extent in industrial applications compared to the traditional ?normally open? and ?normally closed? variants. However, เกจวัดแรงดันแก๊สหุงต้ม with simple safety features could be implemented with ?change-over? contacts.
Let?s look at simple machine monitoring, e.g. a coolant unit on a machine tool with visual fault indication (see figure). A pressure switch with a ?change-over? switching function monitors the coolant supply to the tool. If the supply pressure of the coolant is sufficient, then the switching circuit for a green light is manufactured (green light ?on?). If the pump fails, however, and the supply pressure of the coolant drops off, then your switch changes its switching status. It opens the switching circuit for the green light (green light ?off?) and simultaneously closes the switching circuit for the yellow warning light (yellow light ?on?).Thus the machine operator gets a primary visual feedback of any interruption at the coolant supply unit. Naturally, with the correct connection, the ?change-over? could switch other connected loads instead of a warning light, which could, for example, shut the device down or sound a warning hooter.
Use of mechanical versus electronic pressure switches
Through an ever-increasing degree of automation, even in simple machinery, in the last years there’s been a greater use of mechanical switches with ?normally open? and ?normally closed? as redundant safety monitoring for the continuous monitoring with sensors. The most recent developments in modern electronic switches offer the operator, through the simultaneous provision of switching and analogue output signals, a lot better range of opportunities in the design of safety control. Thus, a control with the help of electronic switches can ? through the analogue signal ? continuously monitor system pressure, temperature or level, while also, simultaneously ? through the evaluation of the switch contacts ? fulfilling an unbiased safety function through the monitoring of critical states, whereby hazards to personnel and machinery can be prevented.
Aside from ?change-over?, manufacturers of switches offer a selection of switching functions for several applications, such as ?normally closed? or ?normally open?. With the aid of these switching functions, operators can fulfil almost 100 % of most simple control and safety tasks within machine building.
Note
Further information on mechanical pressure switches and electronic pressure switches can be found on the WIKA website. Should you need any suggestions about the selection of the right switch, your contact will gladly assist you to.
Also read our article
What’s meant by the ?normally open? switching function with pressure switches?

Leave a Reply